single core insulated wire
"
UL1672 sondern Leiter-PVC Isolier-PVC umhülltes Kabel für interne Verdrahtung aus
UL1672 Single Conductor with Extruded Insulation,105℃, 300V, VW-1,60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300V Rated Temperature: -40~105℃ Flame: VW-1, FT1, FT2 Oil ...
UL10455 sondern Leiter-PVC Isolierkabel für elektronische Ausrüstungs-interne Verdrahtung aus
UL10455 Single conductor using extruded non-integral jacket, 90 ℃, 600 V VW-1, 60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Jacket: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:600 V Rated Temperature:90℃ Flame: ...
Isolierte UL10603 FRPE sondern Leiter-Kabel, flexible elektrisches Kabel 26 AWG-Lehre - AWG-Lehre 9 aus
UL10603 Single Conductor with extruded FRPE insulation, 80 ℃, 600 V VW-1 Construction Conductor : Solid or Stranded Insulation: FRPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 600 V Rated Temperature: 80℃ Flame: VW-1, FT1, FT2 Voltage ...
UL3321 sondern Leiter-Kabel-Flachkabel-Draht mit verdrängter XLPE-Isolierung aus
UL3321 Single Conductor with extruded XLPE insulation, 150 ℃, 600 V or 750V VW-1 Construction Conductor : Solid or Stranded Insulation: XLPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 600 V OR 750V Rated Temperature: 150℃ Flame: VW-1, FT1, FT2 ...
Isolierungs-biegen einzelner Leiter-Draht UL3820 XLPE, elektrisches Kabel 30 AWG-Lehre - Kcmil 2000
UL3820 Single Conductor with extruded XLPE insulation, 125℃, 1000 V VW-1 Construction Conductor : Solid or Stranded Insulation: XLPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 1000 V Rated Temperature: 125℃ Flame: VW-1, FT1, FT2 Voltage ...
UL1483 sondern Leiter-Kabel mit nicht integralem Jacken-konserviertem/bloßem kupfernem Leiter aus
UL1483 Single conductor using extruded non-integral jacket, 105 ℃, 600 V VW-1, 60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Jacket: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:600 V Rated Temperature:105℃ Flame...
40 AWG-Lehre - einzelnes Leiter-Kabel mit 10 AWG-Lehre mit verdrängter FRPE-Isolierung UL10602
UL10602 Single Conductor with extruded FRPE insulation, 80 ℃, 300 V VW-1 Construction Conductor : Solid or Stranded Insulation: FRPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 300 V Rated Temperature: 80℃ Flame: VW-1, FT1, FT2 Voltage ...
Elektrisches einzelnes Kabel des Leiter-UL10863 mit verdrängtem FRPE-Isolierungs-Halogen frei
UL10863 Single Conductor with extruded FRPE insulation, 80 ℃, 1000 V VW-1 Construction Conductor : Solid or Stranded Insulation: FRPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 1000 V Rated Temperature: 80℃ Flame: VW-1, FT1, FT2 Voltage ...
PVC Isolier-UL10198 sondern Leiter-Kabel, hitzebeständiges Flachkabel aus
UL10198 Single Conductor with Extruded Insulation,105℃, 300V, VW-1,60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300V Rated Temperature: -40~105℃ Flame: VW-1, FT1, FT2 Oil ...